Online Inquiry

Online Inquiry

Contact us

 Contact Details
Email:info@sigas-group.com
RnD Center:0512-52265350
Shanghai Office:021-64881389
Beijing Office:010-58790992
Product Detail
SA-EC213 PPM Oxygen sensor
Share to:
SA-EC213 PPM Oxygen sensor
Type: SA-EC213 PPM Oxygen sensor
Measurement Gas: Oxygen
Accuracy: 1% FS
Response time: 13s
产品详情

Specifications

  • Sensor Technology:               Micro Fuel Cell

  • Signal Output1:               400 μA ± 120 μA ambient air

  • Measuring Range:           0 - 10 PPM (Min) ;0 - 10000 PPM (Max)                              

  • Response Time T90:        13 Seconds                                                                      

  • Accuracy Full Scale2 :      ± 1% of Signal                                                                    

  • Repeatability F.S.:            ± 0.5%                                                                    

  • Temp Coefficient:            2.54 % / º C                                                                    

  • Operating Temp:             0 to 50 º C                                                                        

  • Storage Temp:                 0 to 45 º C                                                                        

  • Recommended Flow:       0.5 - 2 SCFH                                                                  

  • Humidity :                        0 - 100% RH (Non - Condensing)                                        

  • Expected Life3:                15 - 24 Months                                                                   

  • Storage:                           6 Months                                                                         

  • PCB Connection:              Center   Foil Negative Outer; Foil Positive                            

Specification Notes:  

  1. Signal Output is measured in air at 25 º C, Sea Level.

  2. Accuracy Full Scale is calculated with constant pressure and temperature & proper calibration (90% O2 Value on Full Scale Range).   
    Drastic Temperature change can result in a maximum error of ± 10%.

  3. Expected life is calculated when O2 < 1000 ppm @ 25 º C, Sea Level


>>> download Product instruction here

SIGAS Measurement Engineering Corp.                    | Homepage | Contact us | info@sigas-group.com
RnD & Production Center: Building 15, No. 59, Jiangnan Rd, Changshu, Jiangsu Province | Tel.: +86-(0)512-52265350 Fax: +86-(0)512-52265360

SIGAS Photonics Technology Co.,Ltd.
Room 705, Building 3, NUSP Incubation Center, No.9 Weidi Rd. Qixia District Nanjing China | Tel.: +86-(0)25-85576826  Fax: +86-(0)25-85576826
Beijing Sales Office: Office 1210,No.42, Dong Zhi Men Wai Str. Yu Fei Building, Beijing | Tel.: +86-(0)10-64638812 Fax: +86-(0)25-64638812